T-MAC SYSTEMS Superior Radiation Safety for Generator and Kit Users

The T-MAC system will provide a fast, efficient and safer way to handle elution vials or radiopharmaceutical kits. The T-MAC has a tungsten vial canister, providing exceptional shielding.T Mac Systems

No matter which canister is chosen the user will receive outstanding protection from hand, eye and whole body exposure due to handling of high activity vials. The canister can accommodate a 5-20ml vial that will allow the user to "milk" a generator, reconstitute a kit or draw a dose without removing the vial from the protective shield. In addition, the T-MAC System has Capintec's proprietary hanger design to facilitate the safe handling of generator elution or reconstituted kits. Simply place the shielded vial into the hanger and slide the entire assembly into any Capintec CRC Dose Calibrator for a quick and accurate Mo99 breakthrough measurement or a current Tc99m elution or kit activity measurement. All of this is accomplished without having to handle an unshielded vial.

Maximize your departments regulatory compliance by minimizing your exposure.

Note: When ordering your T-MAC System always specify the generator manufacturer.

 

FEATURES


• Fits all Capintec CRC Dose Calibrators
• Permits Mo-99 and Tc-99m assays with no exposure to unshielded vial
• Allows generator to elute directly into canister
• Reduces hand and eye exposure by factor of 6
• Accommodates 5 to 20 ml vials
• T-MAC offers smaller, unbreakable canister
• Canisters may be used with “Kit” vials to store and measure activity contained, without removing the vial from the shield
• New and improved hanger for smoother operationT Mac Systems Image 2 copy

 

ITEM NUMBERS

T-MAC Complete Assembly (Mallinckrodt) ................................. 5130-3100

T-MAC Complete Assembly(NEN/Dupont) .................................. 5130-0107

Tungsten Canister Only (Mallinckrodt) ........................................ 5120-0193

Tungsten Canister Only (NEN/Dupont) ........................................ 5120-0195

NEN/Dupont Lead Canister............................................................ 5120-2199

Mallinckrodt Lead Canister ........................................................... 5120-2200

Medi-Physics Lead Canister ........................................................... 5120-2055

Holder Only ...................................................................................... 5120-2192

Complete units include canister and holder.